Sep 10, 2021 Leave a message

Annual inspection of cryogenic liquid storage tanks

1. Original data review

Examination of the factory technical documents of the product, including the material certificate and reinspection report of the inner and outer cylinders, the stainless steel welding procedure qualification report, the weld inspection report (including the inspection report of the welding repair part), the hydraulic test report, and the air pressure (Dense) test report, helium leak test report, evaporation rate test report, vacuum test report, etc. ⑵, review the storage tank operation records, and ask the management and operation personnel of the equipment. Whether the pressure is obvious during operation Variety. Whether the safety valve has taken off, whether the evaporation volume has increased, etc.

2. External inspection

In addition to the external inspection according to the requirements of general pressure vessels, the following should be mainly inspected:

(L) Whether various valves open and close normally;

(2) Whether safety accessories such as pressure gauges and level gauges are inspected according to regulations, and whether their use is within the verification period;

⑶, whether there is leakage at the connection of container, pipeline and pipe valve;

⑷. Whether there is "sweating" or "frosting" on the outer surface of the storage tank (especially the outer surface of the top and bottom of the outer cylinder);

⑸ The damage of the outriggers, the foundation sinking, tilting, cracking, and the integrity of the fastening bolts. 


Send Inquiry

whatsapp

Phone

E-mail

Inquiry