High-pressure vaporizers used in air separation plants are currently available in three main types for cylinder-filling applications:
1. Water-Bath Type Vaporizer
The vaporizer consists of coils immersed in a water bath, which is heated by introducing steam. Hot water is used to vaporize liquid oxygen (or liquid nitrogen and liquid argon).
The heat exchange coils are generally fabricated from either a single tube or multiple tubes of relatively large diameter (e.g., φ25 mm × 2–3 mm), bent into a coil configuration. They are usually arranged in a single layer, with headers or manifolds installed at the top and bottom. For single-tube designs, headers are not required. Both the inlet and outlet connections face upwards.
The tubing material must be aluminum or stainless steel. The water temperature is maintained at approximately 80–90°C.
Advantages:
Excellent heat transfer performance.
Compact design with a relatively small footprint.
Lightweight construction.
Relatively safe and reliable operation.
Disadvantages:
- Requires steam consumption, typically at a pressure of approximately 0.4 MPa.
2. Ambient Air Vaporizer (Air-Bath Type)
The heat exchanger is installed in ambient air, which provides the heat required to vaporize the cryogenic liquid.
The heat transfer tubes are constructed using star-shaped, finned composite tubes. The outer tube is made of aluminum, while the inner tube is made of stainless steel.
The finned tube has an outer diameter of approximately 113 mm and an inner diameter of 22 mm, with a wall thickness of 3 mm and eight external fins. These fins enhance heat transfer performance by more than eight times.
The vaporizer is installed vertically, with an overall height of approximately 2 meters.
Each module consists of eight star-shaped tubes connected in series. The vaporization capacity is approximately 50–75 Nm³/h per module. The required number of parallel modules is determined according to the total vaporization capacity.
Headers are installed between the modules and positioned downward. The entire vaporizer is mounted within a structural frame, with connecting plates used to secure the fins.
Advantages:
No steam or electrical power consumption required.
Safe operation.
Simple operating principle.
Disadvantages:
Relatively low heat transfer coefficient.
Large footprint.
Heavy overall weight.
Higher equipment cost.
3. In-Column Vaporizer (Using Process Air as the Heating Medium)
This type of vaporizer is installed inside the air separation column and uses process air as the heating medium.
It forms an integral part of the air separation unit (ASU), functioning as an oxygen heat exchanger. It recovers the refrigeration capacity (cold energy) from liquid oxygen and gaseous oxygen through heat exchange with process air, which is subsequently returned to the column. This helps reduce the overall refrigeration duty of the ASU.
Oxygen heat exchangers are generally designed in either single-tube or double-tube (tube-in-tube) configurations.
Depending on the process design and operating pressure, the pressurized air can flow either through the outer tube or through the annular space between the inner and outer tubes.
For small-scale plants, the heat exchanger is generally designed as a coil using small-diameter copper tubes (φ5 mm × 1 mm or φ6 mm × 1 mm).
The operating pressure on the oxygen side is approximately 15–16 MPa. The air-side operating pressure depends on the process configuration:
Medium-pressure process: 2–4 MPa.
Low-pressure process: approximately 0.55 MPa.
In a 150 Nm³/h air separation plant, the oxygen heat exchanger and main heat exchanger are integrated into one assembly, consisting of multiple coiled concentric tubes. The tube dimensions are approximately φ10 mm × 1 mm and φ5 mm × 1 mm. Silver brazing is used for the tube joints.
Advantages:
Recovers the refrigeration capacity of liquid oxygen and gaseous oxygen.
Reduces the refrigeration duty of the ASU.
Integrates the vaporizer into the ASU process, improving overall energy efficiency.
Does not require an independent external heating source.
Disadvantages:
More complex process and equipment design.
Operating conditions are closely linked to the ASU process and operating parameters.
Not suitable as an independent vaporization unit downstream of a liquid storage tank.
Important note:
The first two types of vaporizers are generally installed downstream of liquid storage tanks for pressurization and vaporization. Since the refrigeration capacity of the vaporized liquid is not recovered, they result in refrigeration losses.
In contrast, the in-column oxygen vaporizer is integrated into the ASU process and recovers the refrigeration capacity, thereby reducing the overall refrigeration consumption of the plant.
Technical terminology recommendation: In international ASU engineering documents, the following terms are commonly used:
水浴式气化器 - Water-Bath Vaporizer
空浴式气化器 - Ambient Air Vaporizer
塔内氧换热器 - In-Column Oxygen Vaporizer / Oxygen Vaporizer Integrated into the Column
Note: The above translation retains the original technical data and design descriptions. For modern engineering applications, material selection, particularly for high-pressure oxygen service, should be verified against applicable oxygen-cleanliness, compatibility and pressure-design requirements.