In practice, it is found that the analyzed purity of gaseous oxygen is always lower than that of liquid oxygen. For example, if the pressure in the main condenser is 0.14 MPa and the liquid oxygen purity is 99.6% O₂, the gaseous oxygen purity is only 99.4% O₂; if the liquid oxygen purity is 99.86% O₂, then the gaseous oxygen purity is 99.6% O₂. How can this be? Is it an analytical error? In fact, this is perfectly normal.
This is because the gaseous oxygen is evaporated from the liquid oxygen, and the liquid oxygen itself is not 100% pure oxygen. Naturally, the higher the oxygen concentration in the liquid oxygen, the higher the concentration of the gaseous oxygen evaporated from it. But why are the two not equal? Suppose the liquid flowing into the condenser-evaporator each minute contains 99.6% O₂, with the remaining 0.4% being nitrogen and other substances whose boiling points are lower than that of oxygen. When this liquid is heated by the gaseous nitrogen on the other side, it evaporates into gas. With the liquid oxygen level held stable, the amount of liquid flowing into the main condenser must equal the amount of gas evaporated from it. Since nitrogen is the more volatile component, during evaporation nitrogen evaporates from the liquid to a greater extent than oxygen does; consequently, the purity of the gaseous oxygen falls short of 99.6%. As a result, the oxygen component entering the main condenser in the liquid exceeds the oxygen component leaving it in the gas, so the oxygen concentration in the liquid oxygen keeps rising - until the purity of the liquid oxygen rises to the point where the gaseous oxygen evaporated from it also reaches 99.6% O₂. At this point, the oxygen components entering and leaving are in balance, and the liquid oxygen purity stabilizes at a value higher than 99.6% O₂ (e.g., 99.86%), beyond which it will not increase further. Thus, with the liquid level in the condenser-evaporator held stable, the liquid oxygen purity in the main condenser is necessarily higher than that of the gaseous oxygen, while the purity of the liquid oxygen flowing into the main condenser is the same as that of the gaseous oxygen. The specific values can be obtained from the vapor-liquid equilibrium diagram.
For plants producing gaseous oxygen, the gaseous oxygen analysis should be taken as the basis. However, analyzing both the gaseous oxygen and the liquid oxygen purities at the same time helps to determine whether the main condenser is leaking.